08

2023

-

03

Installation and use

Author:


Determine the distance between the prime mover and the load according to the connection form of the shaft and the length of the torque transducer. Adjust the distance between

1. Determine the distance between the prime mover and the load according to the connection form of the shaft and the length of the torque transducer. Adjust the distance between the axes of the prime mover and the load relative to the reference plane, so that the coaxiality of their axes is less than Φ 0.03mm, and fix the prime mover and the load on the reference plane.
2. Install the couplings on their respective shafts.
3. Adjust the distance between the torque transducer and the reference plane so that the coaxiality between its axis and the axes of the prime mover and load is less than Φ 0.03mm, and fix the torque transducer on the reference plane.
4. Tighten the coupling and the installation is completed.